CVE-2021-23484
The package zip-local before 0.3.5 are vulnerable to Arbitrary File Write via Archive Extraction (Zip Slip) which can lead to an extraction of a crafted file outside the intended extraction directory. Devamını Oku
The package zip-local before 0.3.5 are vulnerable to Arbitrary File Write via Archive Extraction (Zip Slip) which can lead to an extraction of a crafted file outside the intended extraction directory. Devamını Oku
The package bmoor before 0.10.1 are vulnerable to Prototype Pollution due to missing sanitization in set function. **Note:** This vulnerability derives from an incomplete fix in [CVE-2020-7736](https://security.snyk.io/vuln/SNYK-JS-BMOOR-598664) Devamını Oku
The package keyget from 0.0.0 are vulnerable to Prototype Pollution via the methods set, push, and at which could allow an attacker to cause a denial of service and may lead to remote code execution. **Note:** This vulnerability derives from an incomplete fix to [CVE-2020-28272](https://security.snyk.io/vuln/SNYK-JS-KEYGET-1048048) Devamını Oku
A local privilege escalation vulnerability was found on polkit's pkexec utility. The pkexec application is a setuid tool designed to allow unprivileged users to run commands as privileged users according predefined policies. The current version of pkexec doesn't handle the calling parameters count correctly and ends trying to execute environment variables as commands. An attacker…
Authenticated (admin+) Arbitrary File Download vulnerability discovered in Download Monitor WordPress plugin (versions <= 4.4.6). The plugin allows arbitrary files, including sensitive configuration files such as wp-config.php, to be downloaded via the &downloadable_file_urls[0] parameter data. It's also possible to escape from the web server home directory and download any file within the OS. Devamını Oku
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26. Devamını Oku
Configuration vulnerability in Hitachi Energy LinkOne application due to the lack of HTTP Headers, allows an attacker that manages to exploit this vulnerability to retrieve sensitive information. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26. Devamını Oku
Information Exposure vulnerability in Hitachi Energy LinkOne application, due to a misconfiguration in the ASP server exposes server and ASP.net information, an attacker that manages to exploit this vulnerability can use the exposed information as a reconnaissance for further exploitation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26. Devamını Oku
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J,…
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2):…
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500…
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8…