[webapps] Gitea 1.16.6 – Remote Code Execution (RCE) (Metasploit)
Gitea 1.16.6 – Remote Code Execution (RCE) (Metasploit)
Exploit ile ilgili teknik detaylar için Devamını Oku
Kaynak: Exploit-DB.com RSS Feed
Gitea 1.16.6 – Remote Code Execution (RCE) (Metasploit)
Exploit ile ilgili teknik detaylar için Devamını Oku
Kaynak: Exploit-DB.com RSS Feed
The HoYoVerse (formerly miHoYo) Genshin Impact mhyprot2.sys 1.0.0.0 anti-cheat driver does not adequately restrict unprivileged function calls, allowing local, unprivileged users to execute arbitrary code with SYSTEM privileges on Microsoft Windows systems. The mhyprot2.sys driver must first be installed by a user with administrative privileges. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını…
A flaw was found in the Linux kernel implementation of proxied virtualized TPM devices. On a system where virtualized TPM devices are configured (this is not the default) a local attacker can create a use-after-free and create a situation where it may be possible to escalate privileges on the system. Zafiyet ile ilgili Genel Bilgi,…
A vulnerability has been found in Nintendo Game Boy Color and classified as problematic. This vulnerability affects unknown code of the component Mobile Adapter GB. The manipulation leads to memory corruption. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-208606 is the identifier assigned to…
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was in a CNA pool that was not assigned to any issues during 2022. Notes: none. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: CVE-2022-2078. Reason: This candidate is a reservation duplicate of CVE-2022-2078. Notes: All CVE users should reference CVE-2022-2078 instead of this candidate. All references and descriptions in this candidate have been removed to prevent accidental usage. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını…
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600’s ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled.…
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left…
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the…
GLPI stands for Gestionnaire Libre de Parc Informatique and is a Free Asset and IT Management Software package, that provides ITIL Service Desk features, licenses tracking and software auditing. It was found that in affected versions there is an exposure of private information defined in setup of GLPI (like smtp or cas hosts). Note that…
GLPI stands for Gestionnaire Libre de Parc Informatique and is a Free Asset and IT Management Software package, that provides ITIL Service Desk features, licenses tracking and software auditing. Affected versions were found to not properly neutralize HTML tags in the global search context. Users are advised to upgrade to version 10.0.3 to resolve this…
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*…