CVE-2021-32998
The FANUC R-30iA and R-30iB series controllers are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. INIT START/restore from backup required. Devamını Oku
The FANUC R-30iA and R-30iB series controllers are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. INIT START/restore from backup required. Devamını Oku
The affected Baker Hughes Bentley Nevada products (3500 System 1 6.x, Part No. 3060/00 versions 6.98 and prior, 3500 System 1, Part No. 3071/xx & 3072/xx versions 21.1 HF1 and prior, 3500 Rack Configuration, Part No. 129133-01 versions 6.4 and prior, and 3500/22M Firmware, Part No. 288055-01 versions 5.05 and prior) utilize a weak encryption…
The FANUC R-30iA and R-30iB series controllers are vulnerable to integer coercion errors, which cause the device to crash. A restart is required. Devamını Oku
Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don’t properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets to access several unexpected memory locations. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını…
When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when…
AVEVA System Platform versions 2017 through 2020 R2 P01 does not properly verify that the source of data or communication is valid. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization. Zafiyet ile ilgili Genel Bilgi,…
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
AVEVA System Platform versions 2017 through 2020 R2 P01 uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the software does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location…
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri…