CVE-2026-104136

OpenEMR is a free and open source electronic health records and medical practice management application. Prior to 8.3.0, the new_recall branch of interface/main/messages/save.php accepts a caller-supplied pid without enforcing patient-level or recall-workflow authorization. A low-privilege authenticated user who knows or enumerates a patient identifier can retrieve patient details, contact fields, HIPAA notification preferences, recent appointment information, and existing recall information. This issue is fixed in version 8.3.0.

Bu kayıt NIST NVD kaynağından aktarılmıştır. Etkilenen sürümler, güncel değerlendirme ve üretici referansları için kaynak kaydı inceleyin.